Comparison of Hydrostatic and Pneumatic Testing


Hydrostatic Testing

Pneumatic Testing

Test pressure is normally 30% higher than the design pressure
Test pressure is normally 10% higher than the design pressure
Recommended for high pressure applications
Recommended only for low pressure applications
Test media (Water) used is not compressible by pressure application
Test media (Air) used is compressible by pressure application
Energy stored per unit volume of water under test pressure is very negligible
Energy stored per unit volume of compressed air under test pressure is very high
Needs thorough cleaning after test to
eliminate moisture especially for service which are reactive to moisture / fluids
Easy to clean after testing
Pressure Relief devices are recommended to control sudden increase in pressure during testing
Pressure relief devices are must during test to ensure no over pressurisation
Chances of equipment/ Pipe / test apparatus
failures are very low
Chances of equipment/ Pipe / test apparatus
failures are high
Weight of equipment along with test medium as
water is high hence special attention should be given to floor and supporting arrangements
Weight of equipment with test medium
as air is comparatively less
Needs verification and examination of joints and connections before testing
Needs very careful checking of weld joints thoroughly before testing
Test media can be reused or transferred to other place after testing
Test media can not be reused or transferred to other place after testing
Skilled and semi skilled personnel can carry out the test
Needs involvement of senior experienced staff to monitor the test.
Recommended where large volumes are to be tested at same time (example pipe lines )
If pipe lines are tested should be done with small segmental lengths at a time.
Damages made by failures are less compared to failures in pneumatic testing
Damages made by failures in testing are very huge and extensive
Hydrotest is a regular day to day practice and safe procedure and it can be followed in any work site
Needs special attention and safety precautions
 Pressure changes finite amount by infinitesimal change in volume
 Pressure change proportional to volume change